Lenovo 3000 C200 Computer Hardware User Manual


 
Symptom-to-FRU index
The symptom-to-FRU index in this section lists symptoms and errors and their
possible causes. The most likely cause is listed first, in boldface type.
Note: Do the FRU replacement or other actions in the sequence shown in the
column headed “FRU or action, in sequence.” If replacing a FRU does not
solve the problem, put the original part back in the computer. Do not
replace a nondefective FRU.
This index can also help you determine, during regular servicing, what FRUs are
likely to need to be replaced next.
A numeric error is displayed for each error detected in POST or system operation.
In the displays, n can be any number.
If no numeric code is displayed, check the narrative descriptions of symptoms. If
the symptom is not described there, go to “Intermittent problems” on page 39.
Note
For a device not supported by diagnostic codes in the Lenovo 3000 notebook
computers, see the manual for that device.
Numeric error codes
Symptom or error FRU or action, in sequence
0200
Failure Fixed Disk
1. Reseat the hard disk drive.
2. Load Setup Defaults in BIOS Setup
Utility.
3. Hard disk drive.
4. System board.
021x
Keyboard error
1. Keyboard.
2. System board.
0220
Monitor type does not match CMOS—Run
SETUP
Load Setup Defaults in BIOS Setup Utility.
0230
Shadow RAM Failed at offset:nnnn
System board.
0231
System RAM Failed at offset:nnnn
1. DIMM.
2. System board.
0232
Extended RAM Failed at offset:nnnn
1. DIMM.
2. System board.
0250
System battery is dead—Replace and run
SETUP
1. Charge the backup battery for more
than 8 hours by connecting the ac
adapter.
2. Replace the backup battery and run BIOS
Setup Utility to reset the time and date.
0251
System CMOS checksum bad—Default
configuration use
1. Charge the backup battery for more
than 8 hours by connecting the ac
adapter.
2. Replace the backup battery and run BIOS
Setup Utility to reset the time and date.
Symptom-to-FRU index