Lenovo 3074 Server User Manual


 
9. Note the orientation of the low-prole bracket and position it on the RAID card. Align the two screw
holes in the low-prole bracket with the corresponding screw holes in the RAID card and then install the
screws to secure the bracket.
Figure 44. Installing the low-prole bracket to the RAID card
10. Position the RAID card near the PCI Express card slot. Ensure that the left edge of the RAID card is
inserted into the notch of the RAID card retention bracket 1 . Then, carefully press the RAID card
straight into the slot until it is securely seated and the low-prole bracket also is secured by the riser
card assembly 2.
Figure 45. Installing the RAID card
11. Connect signal cables to the connectors on the new RAID card and the connectors on the hot-swap
hard disk drive backplane. See “Mini-SAS to mini-SAS signal cable connections” on page 29.
12. Reinstall the riser card assembly 2. The procedure is similar to that of the riser card assembly 1. See
“Replacing the riser card assembly 1” on page 143
.
What to do next:
To work with another piece of hardware, go to the appropriate section.
To complete the replacement, go to “Completing the parts replacement” on page 147
. Then, congure
RAID for your server. See “Conguring RAID” on page 56.
Chapter 6. Installing, removing, or replacing hardware 87