Lenovo 4084 Personal Computer User Manual


 
Diagnostic Error Code FRU/Action
001-027-XXX System Conguration/Setup error 1. Run Setup
2. Flash the system. See “Updating (ashing) BIOS
from a disc” on page 560
3. System board
001-032-XXX System Device Controller failure System board
001-034-XXX System Device Buffer Allocation failure
1. Reboot the system
2. Flash the system. See “Updating (ashing) BIOS
from a disc” on page 560
3. Run memory test
4. System board
001-035-XXX System Device Reset condition detected System board
001-036-XXX System Register error System board
001-038-XXX System Extension failure
1. Adapter card
2. System board
001-039-XXX System DMI data structure error 1. Flash the system. See “Updating (ashing) BIOS
from a disc” on page 560
2. System board
001-040-XXX System IRQ failure 1. Power-off/on system and re-test
2. System board
001-041-XXX System DMA failure 1. Power-off/on system and re-test
2. System board
001-195-XXX System Test aborted by user
Information only Re-start the test, if necessary
001-196-XXX System test halt, error threshold exceeded
1. Press F3 to review the log le
2. Re-start the test to reset the log le
001-197-XXX System test warning
1. Make sure the component that is called out is
connected and/or enabled. See Chapter 6 “Using
the Setup Utility” on page 43
2. Re-run test
3. Replace the component that is called out in warning
statement
4. Replace the component under test
001-198-XXX System test aborted
1. If a component is called out, make sure it is
connected and/or enabled. See Chapter 6 “Using
the Setup Utility” on page 43
2. Flash the system and retest. See “Updating (ashing)
BIOS from a disc” on page 560
3. Go to “Undetermined problems” on page 69
001-199-XXX System test failed, cause unknown 1. Go to “Undetermined problems” on page 69
2. Flash the system and re-test
3. Replace component under function test
001-250-XXX System ECC error System board
001-254-XXX 001-255-XXX 001-256-XXX 001-257-XXX
System DMA error
System board
001-260-XXX 001-264-XXX System IRQ error System board
50 ThinkCentre Hardware Maintenance Manual