Lenovo 4168 Laptop User Manual


 
Diagnostic Error Code FRU/Action
018-250-XXX PCI Card Services error 1. PCI card
2. Riser card, if installed
3. System board
020-000-XXX PCI Interface Test Passed
No action
020-0XX-XXX PCI Interface error 1. PCI card
2. Riser card, if installed
3. System board
020-195-XXX PCI Test aborted by user
Information only Restart the test, if necessary.
020-196-XXX PCI test halt, error threshold exceeded
1. Press F3 to review the log le.
2. Restart the test to reset the log le.
020-197-XXX PCI test warning
1. Make sure the component that is called out is
connected and/or enabled. See Chapter 6 “Using the
Setup Utility program” on page 41.
2. Re-run the test.
3. Replace the component that is called out in warning
statement.
4. Replace the component under test.
020-198-XXX PCI test aborted
1. If a component is called out, make sure it is
connected and/or enabled. See Chapter 6 “Using the
Setup Utility program” on page 41
.
2. Flash the system and re-test. See “Updating
(ashing) the BIOS from a disc” on page 180.
3. Go to “Undetermined problems” on page 66.
020-199-XXX PCI test failed, cause unknown 1. Go to “Undetermined problems” on page 66.
2. Flash the system and re-test. See “Updating
(ashing) the BIOS from a disc” on page 180.
3. Replace component under function test.
020-262-XXXPCI system error 1. PCI card
2. Riser card, if installed
3. System board
025-000-XXXIDE interface Test Passed
No action
025-00X-XXX 025-01X-XXX IDE interface failure
1. IDE signal cable
2. Check power supply voltages
3. Reseat IDE signal cable
4. IDE device
5. System board
025-027-XXX IDE interface Conguration/Setup error
1. IDE signal cable
2. Flash the system. See “Updating (ashing) the BIOS
from a disc” on page 180.
3. Reseat IDE signal cable
4. IDE device
5. System board
Chapter 7. Symptom-to-FRU index 55