Diagnostic Error Code FRU/Action
201-XXX-XXX System Memory error
1. Replace the memory module called out by the test
2. System board
202-000-XXX System Cache Test Passed
No action
202-XXX-XXX System Cache error 1. Cache, if removable
2. System board
3. Microprocessor
206-000-XXX Diskette Drive Test Passed No action
206-XXX-XXX Diskette Drive error
1. Diskette Drive Cable
2. Check power supply voltages
3. Diskette drive
4. System board
215-000-XXX CD-ROM Drive Test Passed
No action
215-XXX-XXX CD-ROM Drive error 1. CD-ROM Drive Cable
2. Check power supply voltages
3. CD-ROM drive
4. System board
217-000-XXX Hard Disk Drive Test Passed No action
217-25X-XXX 217-26X-XXX Hard Disk Drive (IDE) error 1. Hard Disk Drive Cable
2. Check power supply voltages
3. Reseat the hard disk drive cable
4. Hard Disk drive (IDE)
5. System board
217-28X-XXX 217-29X-XXX Hard Disk Drive (SCSI) error 1. Hard Disk Drive Cable
2. Check power supply voltages
3. Reseat the hard disk drive cable
4. Hard Disk drive (SCSI)
5. SCSI adapter card
6. System board
220-000-XXX Hi-Capacity Cartridge Drive Test Passed
No action
220-XXX-XXX Hi-Capacity Cartridge Drive error 1. Remove the Hi-Capacity Cartridge Drive and re-test
the system
301-XXX-XXX Keyboard error 1. Keyboard
2. Check and test mouse
3. System board
301-000-XXX Keyboard Test Passed No action
302-000-XXX Mouse Test Passed No action
302-XXX-XXX Mouse error 1. Mouse
2. Check and test Keyboard
3. System board
303-000-XXX Joystick Test Passed No action
303-XXX-XXX Joystick error Remove the Joystick and re-test the system
66 ThinkCentre Hardware Maintenance Manual