Syntax:
del all <range>
del email <range>
del sms <range>
del trap <range>
Description:
The Del here is used for the de-activation of sms, email and trap event.
Argument:
<range>: syntax: 1,5-7, trap number.
Possible value:
available from 1 to 21.
Example:
GSW-2690(alarm-events)# del sms 1-3
GSW-2690(alarm-events)# del email 1-3
GSW-2690(alarm-events)# del trap 1-3
GSW-2690(alarm-events)# del all 1-3
set
Syntax:
set all <range>
set email <range>
set sms <range>
set trap <range>
Description:
The Set here is used for the activation of sms, email and trap event.
Argument:
<range>: syntax 1,5-7, trap number.
Possible value:
available from 1 to 21.
Example:
GSW-2690(alarm-events)# set sms 1-3
GSW-2690(alarm-events)# set email 1-3
GSW-2690(alarm-events)# set trap 1-3
GSW-2690(alarm-events)# set all 1-3