User Manual
Publication date: June, 2005
Revision A1
258
1 - 10M/Half.
2 - 10M/Full.
3 - 100M/Half.
4 - 100M/Full.
5 - 1G/Full. "
-- @@ACTION ruby_port_conf_entry
::= { GSW2690PortConfEntry 3 }
GSW2690PortConfFlwCtrl OBJECT-TYPE
SYNTAX INTEGER(1|0)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The flow control of the port configuration entry.
0 - asymmetric.
1 - symmetric. "
-- @@ACTION ruby_port_conf_entry
::= { GSW2690PortConfEntry 4 }
-----------------------------------------------------------------
GSW2690TrapEntry OBJECT IDENTIFIER ::= { GSW2690Produces 20 }
GSW2690ModuleInserted NOTIFICATION-TYPE
OBJECTS { ifIndex }
STATUS current
DESCRIPTION
"Send this trap when a moudle is inserted to the system. The OID value
means
the port number."
::= { GSW2690TrapEntry 1 }
GSW2690ModuleRemoved NOTIFICATION-TYPE
OBJECTS { ifIndex }
STATUS current
DESCRIPTION
"Send this trap when a moudule is removed from the system. The OID
value means
the port number."
::= { GSW2690TrapEntry 2 }
GSW2690DualMediaSwapped NOTIFICATION-TYPE
OBJECTS { ifIndex }
STATUS current
DESCRIPTION
"Send this trap when the dual media port changed. The OID value means
the port number."
::= { GSW2690TrapEntry 3 }
GSW2690StpStateDisabled NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Send this trap when the operational state of STP is from enabled to
disabled. "