Use To
Robust XON
On
Off
Determine whether the printer communicates availability to the computer.
Notes:
Off is the factory default setting.
This menu item applies only to the serial port if Serial Protocol is set to
XON/XOFF.
Baud
1200
2400
4800
9600
19200
38400
57600
115200
138200
172800
230400
345600
Specify the rate at which data can be received through the serial port.
Notes:
9600 is the factory default setting.
138200, 172800, 230400, and 345600 baud rates are only displayed in the
Standard Serial menu. These settings do not appear in the Serial Option 1,
Serial Option 2, or Serial Option 3 menus.
Data Bits
7
8
Specify the number of data bits sent in each transmission frame.
Note: 8 is the factory default setting.
Parity
Even
Odd
None
Ignore
Set the parity for serial input and output data frames.
Note: None is the factory default setting.
Honor DSR
On
Off
Determine whether the printer uses the DSR Signal.
Notes:
Off is the factory default setting.
DSR is a handshaking signal used by most serial cables. The serial port uses
DSR to distinguish data sent by the computer from data created by electrical
noise in the serial cable. The electrical noise can cause stray characters to
print. Set this to On to prevent stray characters from printing.
SMTP Setup menu
Use To
Primary SMTP Gateway Specify SMTP server gateway and port information.
Note: 25 is the default SMTP gateway port.
Primary SMTP Gateway Port
Secondary SMTP Gateway
Secondary SMTP Gateway Port