72
ENG
ENGLISH
RS-232 CONTROL
25. Off Timer(Repeat Mode/ Time) (Command: f e)
- To set the Off Timer(Repeat Mode/ Time) function.
Transmission
[f][e][ ][Set ID][ ][Data1][ ][Data2][ ][Data3][Cr]
Data1
00: Repeat Off
01: Repeat Once
02. Repeat Daily
03: Repeat from Monday to Friday
04: Repeat from Monday to Saturday
05: Repeat from Saturday to Sunday
06. Repeat on Sunday
Data2
00~17: 00 ~ 23 Hours
Data3
00~3B: 00 ~ 59 Minutes
* Enter “fe [Set ID] ff” for checking Off Timer(Repeat
mode/ Time) values.
* Check if Time1 and Time2 have been set before
setting this function.
Acknowledgement
[e][ ][Set ID][ ][OK/NG][Data1][Data2][Data3][x]
26. On Timer(Repeat Mode/ Time) (Command: f d)
- To set the On Timer(Repeat Mode/ Time) function.
Transmission
[f][d][ ][Set ID][ ][Data1][ ][Data2][ ][Data3][Cr]
Data1
00: Repeat Off
01: Repeat Once
02. Repeat Daily
03: Repeat from Monday to Friday
04: Repeat from Monday to Saturday
05: Repeat from Saturday to Sunday
06. Repeat on Sunday
Data2
00~17: 00 ~ 23 Hours
Data3
00~3B: 00 ~ 59 Minutes
* Enter “fd [Set ID] ff” for checking On Timer(Repeat
mode/ Time) values.
* Check if Time1 and Time2 have been set before
setting this function.
* On Timer Input command should be executed
followed just after executing this command to set On
Timer schedule properly.
Acknowledgement
[d][ ][Set ID][ ][OK/NG][Data1][Data2][Data3][x]
24. Time 2(Hour/ Minute/ Second) (Command: f x)
- To set the Time 2(Hour/ Minute/ S) values.
Transmission
[f][x][ ][Set ID][ ][Data1][ ][Data2][ ][Data3][Cr]
Data1
00~17: 00 ~ 23 hours
Data2
01~3B: 00 ~ 59 minutes
Data3
01~3B: 00 ~ 59 seconds
* Enter “fx [Set ID] ff” for checking Time 2 values.
* This command won’t work if Time 1 has not been
set in advance.
Acknowledgement