LG Electronics 72WX70MF Computer Monitor User Manual


 
73
ENG
ENGLISH
CONTROLLING THE MULTIPLE PRODUCT
60. Backlight (Command: m g)
To adjust the screen backlight.
Transmission
[m][g][ ][Set ID][ ][Data][Cr]
Data 00 to 64: Backlight 0 to 100
Acknowledgement
[g][][set ID][][OK/NG][Data][x]
** It may not be supported depending on the model.
61. PC Power Control (Command: d t)
To control the PC power if the PC and the monitor
are synchronized.
Transmission
[d][t][ ][Set ID][ ][Data][Cr]
Data
00: Synchronized (When the monitor is off, the PC is
also turned off.)
01: Not synchronized (The monitor is off but the PC
is on.)
** It may not be supported depending on the model.
Acknowledgement
[t][ ][Set ID][ ][OK][Data][x]
Data
00: Synchronized (When the monitor is off, the PC is
also turned off.)
01: Not synchronized (The monitor is off but the PC
is on.)
62. PC Power (Command: d s)
Control the PC power.
Transmission
[d][s][ ][Set ID][ ][Data][Cr]
Data 00: PC is turned off.
01: PC is turned on.
** It may not be supported depending on the model.
Acknowledgement
[s][ ][Set ID][ ][OK][Data][x]
Data 00: PC is turned off.
01: PC is turned on.
63. Reading luminance values (Command: m u)
Reads luminance values.
Transmission
[m][u][ ][Set ID][ ][FF][Cr]
Acknowledgement
[u][][SetID][][OK/NG][Data1][Data2][Data3][Data4]
[Data5][Data6][Data7][x]
Data1 00-64 backlight 0-100
Data2 00-ff: Upper 2-byte of CA210 measured value
Data3 00-ff: Lower 2-byte of CA210 measured value
CA210 measured value Hex: 0000-ffff, Decimal: 0 - 65535
Data4 00-ff: Upper 2-byte of BLU measured value
Data5 00-ff: Lower 2-byte of BLU measured value
Data6 00-ff: Upper 2 bytes of BLU No. 2 sensor
measured value
Data7 00-ff: Lower 2 bytes of BLU No. 2 sensor
measured value
BLU measured value Hex: 0000-ffff, Decimal: 0 - 65535
* CA210 measured value is entered through the
calibration procedure during final assembly. Default
value is 0 before calibration.