10. DEFAULT SETTINGS
In order to restore the default settings the IPower
Control must be started in boot mode (see section
7). Launch IPCnet_conf.exe.
After the program has opened, all IPower Control
units which are on the network will be listed on the
left hand side of the program window. Select the
one for which the setting should be restored and
click on Program Device/Format Eeprom.
Please note that all current settings will be deleted.
When the IPower Control is restarted the default
settings will be loaded.
After the default settings have been restored the
IPower Control must be set up again (section 1).
11. TECHNICAL DATA
Network Connection: 10Mbit 10Base-T Ethernet
Network protocol: TCP/IP
Switched power (per port): max. 2000W
Switched power (total): max. 3000W
Operating temperature: 0
o
C – 50
o
C
Dimensions: 19” / 1U height
Note: The IPower Control was developed for use with IT devices. Using the
IPower Control with devices which have a high initial current surge (like halogen
lam
p
s
)
is not recommended.