Listen Technologies RP 6004 Network Card User Manual


 
Danish Interpretation Systems User Manual
Manual 01 18 04466
10
System Setup
General guidelines
Connect the RP 6004 to the various units using Cat
5 FTP or STP cables. Please observe the following
guide lines:
Maximum cable length in one chain is 200
m without repeater. This includes
interconnection cables between the units.
The max. usable cable length depends on
the units connected and length of feeding
cables etc.
Maximum cable length in one chain when
using repeaters is 650 m.
As the RP 6004 Repeater is repeating only
one of the four outputs A (A1 or A2) or B
(B1 or B2) the max. number of languages
configured on the four outputs (1, 2, 3 and
4) is totally max. 16.
If more languages are required, Interpreter
sets for those languages have to be divided
between both chains (A or B) on the CU
6010. Normally the languages are supposed
to be divided equally on chains A (A1 or
A2) and B (B1 or B2).
If the last unit in one chain is a CS 6032
Channel Selector, this unit has to be
terminated with an external termination, as
the CS 6032 does not have an internal
termination.
Built into 19” Racks
The optional 19”-Brackets allow the unit to be
mounted in a rack with either the front (connector
side) or the blank backside to the front side of the
rack. The height is 1HU and allows units to be
stacked using only 44mm rack height.
Can also be mounted at the back of the rack cabinet
freeing the space at the front of the rack. The
cabinet shall then be deep enough to allow this.