q Power LED
Those LED light up when Power is available on the
connector next to the LED
q Incoming data LED
Those LED flashes, when the unit receives
incoming data from connected units on the
connector next to the LED.
System design
There are no settings to be done on the RP 6004
Repeater.
However it is important to observe, that the unit is
only repeating one of the chains on the CU 6010
Central Unit.
And as so, the specification, which applies to each
of the chain outputs on the CU 6010 Central Units
does also apply to all the repeated outputs in total.
So when designing a system to incorporate RP 6004
Repeaters, bare in mind, that as the RP 6004
Repeater is repeating only one of the four outputs A
(A1 or A2) or B (B1 or B2) the max. number of
languages configured on the four outputs (1, 2, 3
and 4) is totally max. 16.
If more languages are required, Interpreter sets for
those languages have to be connected either to an
other RP 6004 Repeater, which is connected to the
other of the two chains (A or B) on the CU 6010, or
directly to the other of the two chains (A or B) on a
CU 6010.
‘Repeated chain’ connector
When connecting the RP 6004 Repeaters to the CU
6010 the first RP 6004 is connected to the ‘Loop
through’ connector. The next RP 6004 Repeaters
can be connected to either the other ‘Loop through’
connector or to one of the ‘Repeated out’
connectors. If using the ‘Repeated’ outputs
maximum two more RP 6004 Repeaters can be
connected extending the maximum cable length in
one chain up to 650 m. The above schematic is
showing the connection using the ‘‘Repeated out’
connectors.