CONFIGURATION OF THE SCANNER TO THE HOST SYSTEM
The scanner is shipped from the factory programmed to a set of default conditions noted in the ScanSelect®
Scanner Programming Guide by an asterisk that appears before the brief definition next to the bar code.
In order for the scanner to communicate with the host system properly, it needs to be programmed to meet your
specific scanning needs. Since each host system is unique, the scanner must be configured to match the host
system requirements. The scanner can be configured by entering program mode and scanning the appropriate
bar codes that appear in the ScanSelect® Scanner Programming Guide. (When using ScanSet®, refer to the
ScanSet documentation for information on how to configure the scanner.)
1. Connect the scanner to the host system
(Refer to the Scanner Connections to the Host section in this guide).
2. Enter program mode by scanning the ENTER/EXIT program mode bar code.
(The unit will beep three times)
3. Scan the appropriate bar code(s) that appear in the ScanSelect Scanner Programming Guide.
(Reveal only one bar code to the scanner each time. With your hand, cover the bar code that should not
be scanned.)
4. Exit program mode by scanning the ENTER/EXIT program mode bar code again.
(The new options will be saved and the scanner is ready for normal operation.)
Caution:
To maintain compliance with applicable standards, all circuits connected to the scanner must meet
the requirements for SELV (Safety Extra Low Voltage) according to EN 60950.
To maintain compliance with standard CSA C22.2 No. 950/UL 1950 and norm EN 60950, the power
source should meet applicable performance requirements for a limited power source.
3