Metrologic Instruments IS1650 Barcode Reader User Manual


 
7
INTRODUCTION
DESIGN SPECIFICATIONS (CONT.)
IS1650 DESIGN SPECIFICATIONS
ELECTRICAL
Input Voltage: 5.0VDC ± 0.25V
Peak = 2 W (Typical)
Operating = 1.65 W (Typical)
Power:
Idle / Standby = 800 mW (Typical)
Peak = 400 mA (Typical)
Operation = 330 mA (Typical)
Current:
Idle / Standby = 160 mA (Typical)
DC Transformer: Class 2; 5.2VDC @ 1 AMP
For Regulatory Compliance information, see pages 40- 42
ENVIRONMENTAL
Operating = 0°C to 40° (32° to 104°F)
Temperature:
Storage = -40°C to 60°C (-40°F to 140°F)
Humidity: 0% to 95% Relative Humidity, Non-Condensing
Light Levels: Up to 100,000 Lux (9,290 Footcandles)
Shock: Designed to withstand 1.0 m (3.3 ft.) drops
Contaminants: Sealed to resist airborne particulate contaminants
Ventilation: None required
Specifications are subject to change without notice.