Metrologic Instruments IS8000 Series Scanner User Manual


 
27
APPENDIX C
IS8000 Series Pinout Connections
DESCRIPTION PIN SIGNAL
1Ground
2 RS-232 Receive Input
3 RS-232 Transmit Output
4 CTS Input
5 RTS Output
6 Reserved
7Ground
8 Reserved
9 RS-422 Receive – (B-)
10 RS-422 Receive + (A+)
Connector Type on Scanner
DB25P (D-Type 25 Pin Male)
11 RS-422 Send + (Y+)
12 RS-422 Send – (Z-)
13 Ground
14 Ground
15 Light Pen Source
16 Light Pen Data
17 Reserved
Function:
Communication Pinouts for
RS-232/RS-422 and Light Pen Emulation.
18 Reserved
19 Open
20 DTR Input
21 Reserved
22 Reserved
23 Reserved
24 Reserved
25 Ground
RS-232 Cable Note: Cables for RS-232
should leave the RS-422 pins unterminated
at the scanner.
RS-422 Cable Note: Cables for RS-422
should leave the RS-422 should leave the
RS-232 transmit and receive pins
unterminated at the scanner.
DESCRIPTION PIN SIGNAL
1 RS-232 Receive Data (Input)
2 Clear to Send (Output)
3 Reserved
4 Reserved
5Triac +
6 Sensor +
7 Sensor Alarm +
8 Reserved
9 RS-232 Transmit Data (Output)
10 Request to Send (Input)
Connector Type on Scanner:
DA15P (D-Type 15-Pin Male)
11 Signal Ground
12 Reserved
13 Triac -
14 Sensor -
Function:
Auxiliary RS-234 industrial Interface Port
15 Sensor Alarm -
IS8400/IS8500/IS8800
IS8300