Metrologic Instruments MS1890 Scanner User Manual


 
10
I
NSTALLING THE
S
CANNER TO THE
H
OST
S
YSTEM
IBM MS1890-11
1. Turn off the host device.
2. Plug the male 10-pin RJ45 end of the
MVC cable into the 10-pin socket on
the MS1890. There will be an audible
click when the connector lock
engages.
3. Slide the protective cable boot up the
cable, over the connector and onto
the end of scanner handle.
4. Connect the other end of the MVC
cable to the host device.
5. Turn on the host device.
6. The MS1890 will start to initialize.
All LEDs (yellow, white, and blue) will
light for approximately 2 seconds then
start to alternately flash. When the
scanner has finished initializing the
LEDs will stop flashing and the unit
will beep 3 times indicating that the
scanner is ready for use.
Plugging the scanner into a port on the host system does not guarantee
that scanned information will be communicated properly to the host
system. The scanner is shipped from the factory configured with default
settings. Please refer to the MetroSelect Single-Line Configuration
Guide (
MLPN
00-02544) or MetroSet2’s help files for instructions on
changing the scanner’s configuration. In addition, please check that the
scanner and host system are using the same communication protocol.
See page 6.