Metrologic Instruments MS2221 / MS2222 Scanner User Manual


 
SCANNER AND CABLE TERMINATIONS
CABLE CONNECTOR CONFIGURATIONS
The following cables are examples of some of the standard cables that may be shipped with the StratosS scanner.
Please keep in mind that every application is unique and the cables received with the StratosS may be custom cables that are
not shown below.
RS232 Interface Cable,
MLPN 57-57210x-N-3
Pin
Function
**
9-Pin D-Type Connector
1
No Connect
2 RS232 TX Output
3 RS232 RX Input
4 DTR Input
5 Power/Signal Ground
6 DSR Output
7 CTS Input
8 RTS Output
9
No Connect
Full Speed USB Cable,
MLPN 57-57201x-N-3 or MLPN 57-57227x-N-3
Pin
Function
**
Locking,
Type A
57-57227x-N-3
Non-Locking, Type A
57-57201x-N-3
1 PC+5V USB
2 Data -
3 Data +
4 Ground
IBM 46xx Cable,
MLPN 57-57212x-N-3
Pin
Function
**
4-Pin SDL
1 Signal Ground
2 IBM A+
3 IBM B -
4
No Connect
OCIA Cable,
MLPN 57-57016x-N-3
Pin
Function
**
9-Pin D-Type Connector
1 Shield Ground
2 R Data
3 R Data Return
4 Clock Out
5 Signal Ground
6 OCIA Clock In Return
7 Clock Out Return
8 Clock In
9
No Connect
** All signals are referenced from the StratosS scanner.