Metrologic Instruments MS2322 Scanner User Manual


 
35
SCANNER OPERATION
INDICATOR DESCRIPTIONS
Diagnostic Indicator Display
ERROR
CODE
DESCRIPTION
11
SWITCH ERROR – The switch used for volume selection or sleep mode is detected in error (always closed). The
condition is self-correcting if possible. If the error persists, return the unit for repair at an authorized service center.
The scanning operation can continue with this error active.
21
LASER #1 (VERTICAL) ERROR – The laser in the vertical scanning subsystem denotes a failure. The scanner
will try three times to correct the laser operation. If the laser error persists, the vertical scanning subsystem will be
shut down and this error code will remain on the Diagnostic Indicators.
22
LASER #2 (RIGHT HORIZONTAL) ERROR – The right laser in the horizontal scanning subsystem denotes a
failure. The scanner will try three times to correct the laser operation. If the laser error persists, and the left
horizontal laser (#3) is also in error, the horizontal scanning subsystem will be shut down and this error code will
remain on the Diagnostic Indicators.
23
LASER #3 (LEFT HORIZONTAL) ERROR – The left laser in the horizontal scanning subsystem denotes a failure.
The scanner will try three times to correct the laser operation. If the laser error persists, and the right horizontal
laser (#2) is also in error, the horizontal scanning subsystem will be shut down and this error code will remain on
the Diagnostic Indicators.
31
MOTOR #1 (VERTICAL) ERROR – The motor in the vertical scanning subsystem denotes a failure. The scanner
will try three times to correct the motor operation. If the motor error persists, the vertical scanning subsystem will
be shut down and this error code will remain on the Diagnostic Indicators.
32
MOTOR #2 (HORIZONTAL) ERROR – The motor in the horizontal scanning subsystem denotes a failure.
The scanner will try three times to correct the motor operation. If the motor error persists, the horizontal scanning
subsystem will be shut down and this error code will remain on the Diagnostic Indicators.