MS2321 / MS2322 SCANNER DESIGN SPECIFICATIONS
Design Specifications
Operational
Light Source: VLD 650 nm
Peak Laser Power: <2.2 mW
Maximum IR LED Output:
50μW per IEC 60825-1 measurement procedure
Horizontal Depth of Field: 0 mm - 152 mm (0"- 6") for 0.33 mm (13 mil) Bar Code
Vertical Depth of Field: 0 mm - 216 mm (0"- 8.5") for 0.33 mm (13 mil) Bar Code
Scan Speed: 5840 Scan Lines per Second
No. of Scan Lines: 66 (38 Horizontal / 28 Vertical)
Motor Speed: 4800 / 6000 RPM (Horizontal / Vertical )
Min Bar Width: 0.152 mm (6.0 mil)
Decode Capability: All Standard 1-D Bar Codes, RSS-14, RSS-Expanded, and RSS-14 Limited Bar Codes
System Interfaces: RS232, Aux RS232, RS485
S
, USB, and OCIA
Print Contrast: 35% Minimum Reflectance Difference
No. Characters Read: Up to 80 data characters. Maximum number will vary based on symbology and density.
Beeper Operation: 7 Tones or No Beep; 3 Volume Settings
Blue Laser ON, Ready to Scan
Indicators (LED):
White Good Read, Decoding
Mechanical
MS2321 L x W x H: 508 mm (20") Length 290 mm (11.4") Width 181 mm (7.1") Tower Height
MS2322 L x W x H: 420 mm (16.5") Length 292 mm (11.5") Width Counter 181 mm (7.1") Tower Height
Depth (Below Counter): 100 mm (3.9"), All Models
Weight (with Platter): MS2321, 7.48 kg (16.45 lbs.) MS2322, 6.93 kg (15.25 lbs.)
Electrical
Voltage Supply: 1.5A @ +5V / 1.5A @ +12V
Power: Operating, 14.25 Watts Standby, 3.25 Watts
Current: Operating, 1A @ 5V / 0.75A @ 12V Standby, 0.44 A @ 5V / 0.08A @ 12V
DC Transformers: Class II; 5VDC @ 1.5A; 12VDC @ 1.5A
Current Limits on Integrated
Scale and/or Scale Display:
Do not exceed maximum current of 12V @ 0.2A / 5V@ 0.3A
For Regulatory Compliance Information refer to pages 55 - 57.
Environmental
Operating Temperature: 0°C to 40°C (32°F to 104°F)
IP Rating: IP 55
Light Levels: 4842 Lux (450 footcandles)
Storage Temperature: -40°C to 60°C (-40°F to 140°F)
Humidity: 5% to 95% Relative Humidity, Non-Condensing
Contaminants: Sealed to resist airborne particulate contaminants.
Ventilation: None Required
Specifications are subject to change without notice.