Metrologic Instruments MS9590i Barcode Reader User Manual


 
30
DESIGN SPECIFICATIONS
MS9590i Series Specifications
MECHANICAL
Height H
1
: 160 mm (6.30")
H
2
: 41 mm (1.60")
Width W
1
: 65 mm (2.56")
W
2
: 25.4 mm (1.00")
Depth: 100 mm (3.93")
Weight: 150g
ELECTRICAL
Input Voltage: 5VDC ± 0.25V
Operating = 650 mW typical
Power:
Standby = 375 mW typical
Operating = 130 mA @ 5VDC typical
Current:
Standby = 75 mA @ 5VDC typical
DC Transformers: Class 2; 5.2V @ 1A
For regulatory compliance information see pages 35 – 37.
ENVIRONMENTAL
Operating = 0°C to 50°C (32°F to 122°F)
Temperature:
Storage = -40°C to 60°C (-40°F to 140°F)
Humidity: 5% to 95% relative humidity, non-condensing
Light Levels: Up to 4842 Lux (450 footcandles)
Shock: Designed to withstand 1.8 m (5.91 ft.) drops
Environmental:
Sealing
IP54