REG_ADCLO (base+0Ah): ADC command, status, and result low byte (read/write)
Writing to this register starts a new A/D conversion. You should only do this
when the ADC is idle.
Command bits: 0000dccc
d: 0:single-ended, 1=differential
ccc: Channel.
d
c
c
c
Conversion
0
0
0
0
AIN0 relative to AGND
0
0
0
1
AIN1 relative to AGND
0
0
1
0
AIN2 relative to AGND
0
0
1
1
AIN3 relative to AGND
0
1
0
0
AIN4 relative to AGND
0
1
0
1
AIN5 relative to AGND
0
1
1
0
AIN6 relative to AGND
0
1
1
1
AIN7 relative to AGND
1
0
0
0
Differential AIN0(+) - AIN1(-)
1
0
0
1
Differential AIN1(-) - AIN0(+)
1
0
1
0
Differential AIN2(+) - AIN3(-)
1
0
1
1
Differential AIN3(-) - AIN2(+)
1
1
0
0
Differential AIN4(+) - AIN5(-)
1
1
0
1
Differential AIN5(-) - AIN4(+)
1
1
1
0
Differential AIN6(+) - AIN7(-)
1
1
1
1
Differential AIN7(-) - AIN6(+)
Reading REG_ADCLO returns status and result bits.
Result bits: rrrr00pb
p: ADC present. If 1, the ADC is available. If 0, the ADC is not mounted, and
you should not write to REG_ADCLO.
b: Busy. 0 = ADC idle. The previous result can be read, and a new conversion can
be started. 1 = conversion in progress. All result bits are invalid when b=1.
rrrr: Four least-significant bits of the conversion result. Only valid when b=0.
REG_ADCHI (base+0Bh): ADC result, high byte (read only)
Reading this register returns the eight most-significant bits of the conversion
result. Only valid when the ADC is idle.