7
Figure 3-2. Attach mounting brackets with screws
B. After attaching both mounting brackets, position the MIL-S8000G
switch in the rack by lining up the holes in the brackets with the
appropriate holes on the rack. Secure the switch to the rack with a
screwdriver and the rack-mounting screws.
Figure 3-3. Mounting the MIL-S8000G in an EIA standard 19-inch Rack
Note: For proper ventilation, allow at least 4 inches (10 cm) of clearance
on the front and 3.4 inches (8 cm) on the back of the switch. This is
especially important for enclosed rack installation.
Power On
Connect the power cord to the power socket on the rear panel of the
switch. The other side of power cord connects to the power outlet. The
internal power supply in the Switch works with AC in the voltage range
100-240VAC, frequency 50~60Hz.
Check the power indicator on the front panel to see if power is properly
supplied.