BATTERY SYSTEM
Typical Recharge Time
Typical Battery Life
Battery Quantity/Rating
3-5 years, depending on discharge cycles and ambient temp
4-6V9Ah
4-6V9Ah
8 hours from total discharge
4-6V9Ah
Battery Type
Sealed, Non-Spillable, Maintenance Free, Value Regulated Lead Acid
System Voltage
24VDC
24VDC 24VDC
Runtime: Full Load
Runtime: Half Load
7-Minutes
9-Minutes
13-Minutes
3-Minutes
4-Minutes6-Minutes
SURGE PROTECTION AND FILTERING
Audible noise at 1 m (3 ft.)
10/100 Base-T surge protec-
tion let-through (as a percent-
age of an applied +/-6 kV 1.2/
50 us, 500 a 8/20 uS test)
Telephone line surge protec-
tion let-through (as a percent-
age of an applied +/-6 kV 1.2/
50 us, 500a 8/20 uS test)
Noise filter
Surge voltage let-through (as
a percentage of an applied
ANSI C62.41 Cat. A +/-6 kV)
Surge response time
Surge current capability
Surge energy rating
800 J
0 ns (instantaneous) normal mode; <5 ns common mode
<5%
Normal and common mode EMI/RFI suppression
<45 dBA
<1%
<5%
6500 Amps total
ENVIRONMENTAL
Operating Temperature (max)
Operating/Storage Humidity
Operating Elevation
0 to 40°C (+32 to 104°F)
95% Non-Condensing
0 to 3,000m (0 to 10,000 ft)
PHYSICAL
Weight - Net
Size - Net
H X D X W
Size - Shipping
H X D X W
Weight - Shipping
42.3 lb
19.2 Kg
51.2 lb
23.2 Kg
51.2 lb
23.2 Kg
1.75 x 24 x 17"
44.5 x 610 x 432 mm
5.2 x 27.6 x 20.9"
132 x 701 x 531 mm
52 lb
23.6 Kg
61 lb
27.7 Kg
61 lb
27.7 Kg
REGULATORY COMPLIANCE
Safety and approvals
EMC Verification
UL1778, cUL (CSA 22.2 no. 107.1)
FCC Class A, CE certified
Storage Elevation
0 to 15,000m (0 to +50,000 ft)
Storage Temperature -15 to +45°C (+5 to +113°F)