Pocket
R11terence
Guide
6.
CUSTOMER
DATA
ENTRY REGISTERS
Load
Default
Data
&.tn
Defaults
are
listed
for
each
register.
On a
new
Installation,
the
default
data
must
be
loaded as
follows.
1.
Ensure
Power
Supply
is
OFF.
2.
$et
all
Control
Card
Switches
OPEN.
3.
Switch
Power
Supply
ON.
Wait
for
Control
Card
LED
to
show
?. (The Console
displays
LOAD DEFAULT DATA?).
4.
Within
10 seconds,
toggle
Status
Switch
1
to
the CLOSED
position
and
then
back
to
OPEN.
Walt
for
the
Control
Card
LED
to
dlsplav
A.
(The
Console
displays
DEFAULT
DATA
LOAD-
ED).
S.
Set
Control
Card
Status
Switches
as
required.
Refer
to
Table
6-1.
·
TABLE
6-1
CONTROL CARD STATUS SWITCH FUNCTIONS
Switch
Function
1
Programming:
OPEN
-
Security
Code
Required
CLOSED -
No
Securltv
Code Required
2 OPEN -
Test
Line Disabled
CLOSED-
Test
line
Enabled
3
NOT
USED
4
NOT USED - MUST
BE
SET
TO
OPEN
Page