EN – 17
ENGLISH
4 SIGNAL
MEMORY CALL ........
Use to select AUTO, USER 1 or USER 2. See below.
HORIZ. POSITION ....
Use to adjust the horizontal position of the image.
VERT. POSITION .....
Use to adjust the vertical position of the image.
FINE SYNC. ....... Use to synchronize the projector with PC input signals so
that the image is not blurred.
TRACKING ......... Use to avoid image noise such as wide stripes.
COMPUTER INPUT ....
The unit adjusts itself automatically when connected to a
DVD player with a component video output (Y, CB, CR). In
the case ( Y, PB, PR). In the case the projector is connected to
equipment that includes RGB output terminal, adjust to
RGB mode.
HOLD .................. Adjusts the image when flagging occurs near the top of the
screen.
5 SIGNAL - USER (Normally, there is no need for adjustments.)
CLAMP POSITION/
CLAMP WIDTH .........
If you use something similar, the brighter colors of the
projected image may become blurred. In this case, adjust
CLAMP POSITION or CLAMP WIDTH.
HORIZ.PIXELS .. Use to adjust the width of the image. The image size grows
wider as the number increases. (Adjust to the horizontal
pixels of the input signal for normal setting.)
VERT.LINES ...... Use to adjust the height of the image. The image size grows
higher as the number increases. (Adjust to the vertical lines
of the input signal for normal setting.)
PLL ...................... Use to adjust the image when skewed on top. Select AUTO for
normal setting.
VERT.SYNC. ...... Use to adjust the image when its motion does not run
smoothly. Select AUTO for normal setting.
SHUTTER(U) ..... Use to adjust the image when the noise etc. appears on top part of image.
SHUTTER(L) ...... Use to adjust the image when the noise etc. appears on bottom part of image.
SHUTTER(LS).... Use to adjust the image when the noise etc. appears on left side of image.
SHUTTER(RS) ... Use to adjust the image when the noise etc. appears on right side of image.
User memory for signal setting
This projector can memorize the maximum of 2 signal menu settings.
Memorizing the setting
1. Select MEMORIZE in the SIGNAL menu, and press the ENTER button.
2. Press the $ or % button to select the memory which you wish to record (USER 1 or USER 2).
3. Press the ENTER button.
Initialite the setting which has been changed (Default)
Select RESET in the SIGNAL menu, and press the ENTER button.
• When initializing, selection buttons will not work for about 2 - 18 seconds.
Select the user setting
Select MEMORY CALL in SIGNAL menu, and press the $ or % button to select the memory (USER 1 or USER 2).
Reset the recorded setting
1. Select DELETE in the SIGNAL menu, and press the ENTER button.
2. Press the $ or % button to select the memory which you wish to reset (USER 1 or USER 2).
3. Press the ENTER button.
The recorded setting will be reset.
CLAMP POSITION
SIGNAL-USER
0
CLAMP WIDTH 0
HORIZ. PIXELS 0
PLL AUTO
SHUTTER(RS) 0
VERT. LINES 0
VERT. SYNC. AUTO
SHUTTER(LS) 0
SHUTTER(L) 0
SHUTTER(U) 0
R G B
R G B
A
U
Opt
MEMORY CALL
SIGNAL
AUTO
HORIZ. POSITION 0
VERT. POSITION 0
TRACKING 0
COMPUTER INPUT RGB
FINE SYNC. 0
HOLD AUTO
USER MEMORIZE DELETE DEFAULT