35
Others
34
3
Remove the lamp cover.
Loosen the 2 screws, then pull up to the
direction of the arrow with your fingers on the
area shown in the figure to remove the lamp
cover.
4
Pull out the lamp.
Loosen the 2 screws holding the lamp in place,
and pull up the handle to remove the lamp.
5
Mount the new lamp.
Align the orientation, press down until the bottom is
reached, and lock in place using the two lamp
locking screws.
6
Replace the lamp cover.
Align the cover, and press it in, then tighten the
screws loosened in step
3
until the lamp cover is
no longer loose.
7
Reset the lamp timer.
See the lamp’s manual for instructions on resetting
the lamp timer.
Notes and Precautions
Press the button twice to display (a rough guide) the time of lamp use, the Lamp time
item, in the Status display menu.
p.28
It is recommended that the lamp should be replaced after 2,000 hours of use. When
Lamp time reaches 2,000 hours, the
icon and a message will appear. This display
disappears when you press
button.
Attach the lamp cover correctly so that it is not loose. If it is not attached correctly, the
lamp may fail to come on
p.35
, and the lamp’s lifetime may be shortened.
Always replace the lamp with a new one.
The lamp is made out of glass. Do not touch the glass surface with your bare hands,
bang it, or scratch it. (Dirt, jolts, scratches and the like could break the lamp.)
Used Lamps
This projector’s lamps contain trace amounts of environmentally harmful inorganic
mercury. Be careful not to break used lamps, and dispose it in accordance with local
regulations.
Lamp replacement (Continued)
2
1
2
1
1
2
3
4
5
The indicator lights inform you of internal abnormalities.
No power
Problem with projector
Unplug the AC power cord, and contact your dealer.
Lamp went out during use, or won’t come on
Lamp temperature is high so that it is difficult to turn on, the lifetime of
the lamp has ended or the projector is malfunctioning.
Unplug the AC power cord and wait for a short while, then turn the
power back on.
If a lamp burns out, replace it with a new one.
After approx. one minute of abnormal display, the projector returns to
the standby state waiting for internal cool down.
Power went out during use
Internal overheating, or the outside temperature is too high.
Place the projector so that the air intake and exhaust are not blocked.
Unplug the AC power cord and wait for a short while, then turn the
power back on.
Clean the air filter.
p.32
The icon will appear before the power goes out.
After approx. one minute of abnormal display, the projector returns to
the standby state waiting for internal cool down.
Power went out during use
Problem with internal cooling fan.
Unplug the AC power cord, and contact your dealer.
The
icon will appear before the power goes out.
After approx. one minute of abnormal display, the projector returns to
the standby state waiting for internal cool down.
Power went out during use, or power wont come on
The lamp cover is not properly attached.
Unplug the AC power cord, and reattach the lamp cover.
p.34
After approx. one minute of abnormal display, the projector returns to
the standby state waiting for internal cool down.
PRECAUTIONS
Make sure to unplug the AC power cord if something goes wrong.
If the AC power cord is unplugged before cooling is complete, give the lamp enough time
to cool before plugging it back in. If the lamp overheats, it may fail to light. Unplugging the
AC power cord repeatedly when the temperature is high will shorten the life of the lamp.
(Even if you are not concerned about lamp lifetime, the light may not come on if you do
not wait at least 3 minutes.)
(Off)
(Red lit) (Red lit)
Or
(Green lit)
(Green lit)
(Red lit) (Red lit)
Or
(Off)
Or
(Orange lit)
Or
(Orange lit or flashing)
(Red lit or flashing)
(Red lit)
(Orange
flashing)
(Red lit)
POWER
LAMPTEMP
FAN
POWER
LAMPTEMP
FAN
POWERLAMPTEMPFAN
POWER
LAMPTEMP
FAN
POWER
LAMPTEMP
FAN
Trouble indications
Others