Moxa Technologies 5250 Network Card User Manual


 
NPort IA5150/5250 Series User’s Manual Web Console Configuration
5-33
ATTENTION
Consult your Network Administrator or ISP for the proper mail server settings. The Auto
warning function may not work properly if it is not configured correctly. NPort IA5150/5250
SMTP AUTH supports LOGIN, PLAIN, CRAM-MD5 (RFC 2554).
SNMP Trap Server
SNMP trap server IP or domain name
Setting Factory Default Necessity
IP address or Domain Name None Optional
Event Type
Cold start
This refers to starting the system from power off (contrast this with warm start). When performing
a cold start, NPort IA5150/5250 will automatically issue an Auto warning message by e-mail, or
send an SNMP trap after booting up.
Warm start
This refers to restarting the computer without turning the power off. When performing a warm
start, NPort IA5150/5250 will automatically send an e-mail, or send an SNMP trap after rebooting.
Authentication failure
The user inputs a wrong password from the Console or Administrator. When authentication failure
occurs, NPort IA5150/5250 will immediately send an e-mail or send an SNMP trap.
IP address changed
The user has changed NPort IA5150/5250’s IP address. When the IP address changes, NPort
IA5150/5250 will send an e-mail with the new IP address before NPort IA5150/5250 reboots. If
the NPort IA5150/5250 is unable to send an e-mail message to the mail server within 15 seconds,
NPort IA5150/5250 will reboot anyway, and abort the e-mail auto warning.