Moxa Technologies EDS-305 Switch User Manual


 
12
DIP Switch Settings
EDS-308 Series DIP Switches
EDS-305 Series DIP Switches
12345678
ON DIP
12345
ON DIP
ON: Enables the corresponding PORT Alarm. If the port’s link fails, the relay will form an open
circuit and the fault LED will light up.
Off: Disables the corresponding PORT Alarm. The relay will form a closed circuit and the Fault
LED will never light up.
LED Indicators
The front panel of MOXA EtherDevice Switch contains several LED indicators. The function of
each LED is described in the table below.
LED Color State Description
On Power is being supplied to power input P1
P1
AMBER
Off Power is not being supplied to power input P1
On Power is being supplied to power input P2
P2
AMBER
Off Power is not being supplied to power input P2
On
When the corresponding PORT alarm is
enabled, and the port’s link is inactive.
Fault
RED
Off
When the corresponding PORT alarm is
enabled and the port’s link is active, or when the
corresponding PORT alarm is disabled.
On TP port’s 10 Mbps link is active
Blinking Data is being transmitted at 10 Mbps
10M
GREEN
Off TP Port’s 10 Mbps link is inactive
On TP port’s 100 Mbps link is active
Blinking Data is being transmitted at 100 Mbps
100M (TP)
GREEN
Off 100BaseTX Port’s link is inactive
On FX port’s 100 Mbps is active
Blinking Data is being transmitted at 100 Mbps
100M (FX)
GREEN
Off 100BaseFX port is inactive