Panel/Wall Mounting
Mounting the TN-5308-LV/MV on the wall requires 3 screws. Please use the
3 screws packed in the panel mounting kit.
STEP 1: Prepare the 3 screw holes on the wall according to the positions of
the 3 screw holes on the switch shown on the mounting dimension diagram.
STEP 2: Use one screw to go through the top-middle screw hole on the
switch and screw it into the wall.
STEP 3: Screw in the remaining 2 screws through the bottom-left and
bottom-right holes on the switch to the wall.
NOTE
The screw lengths of TN-5308-LV and TN-5308-MV are
different. TN-5308-LV uses M3 * 30 mm screws. TN-5308-MV
uses M3 * 40 mm screws. Please use the screws packed in the
panel mounting kit.
DIN-Rail Mounting (optional)
With the optional DIN-Rail mounting kit
DK-TN-5308 (must be purchased separately),
you can mount the TN-5308-LV/MV on a
35mm DIN-Rail.
STEP 1:
Fix the DIN-Rail attachment plate onto the rear
panel of the switch as shown in the figure at the
right.
STEP 2:
Position the TN-5308-LV/MV on the
DIN-Rail, tilting to hook clamps over
the top edge of the rail.
STEP 3:
Swing the switch down fully onto the
DIN-Rail until both clamps completely
latch.
metal
spring
DIN-Rail
metal
spring
DIN-Rail
To remove the Moxa ToughNet Switch from the DIN-Rail, simply reverse
Steps 2 and 3 above.