MRV Communications MR2228-S2C Switch User Manual


 
29
Appendix B: Cables
Twisted-Pair Cable and Pin Assignments
Caution: DO NOT plug a phone jack connector into any RJ-45 port. Use only
twisted-pair cables with RJ-45 connectors that conform with FCC standards. For
10/100BASE-TX connections, the twisted-pair cable must have two pairs of wires.
For 1000BASE-T connections the twisted-pair cable must have four pairs of wires.
Each wire pair is identified by two different colors. For example, one wire might be
green and the other, green with white stripes. Also, an RJ-45 connector must be
attached to both ends of the cable.
Caution: Each wire pair must be attached to the RJ-45 connectors in a specific
orientation. (See “Cabling Guidelines” on page 4-1 for an explanation.)
The figure below illustrates how the pins on the RJ-45 connector are numbered.
Be sure to hold the connectors in the same orientation when attaching the wires to
the pins.
10BASE-T/100BASE-TX Pin Assignments
Use unshielded twisted-pair (UTP) or shielded twisted-pair (STP) cable for RJ-45
connections: 100-ohm Category 3 or better cable for 10 Mbps connections, or
100-ohm Category 5 or better cable for 100 Mbps connections. Also be sure that
the length of any twisted-pair connection does not exceed 100 meters (328 feet).
The RJ-45 ports on the switch base unit support automatic MDI/MDI-X operation,
so you can use straight-through cables for all network connections to PCs or
servers, or to other switches or hubs. In straight-through cable, pins 1, 2, 3, and 6,
at one end of the cable, are connected straight through to pins 1, 2, 3, and 6 at the
other end of the cable. When using any RJ-45 port on this switch, you can use
either straight-through or crossover cable.