Multi-Link ACP-300 Computer Hardware User Manual


 
REGISTER 15 Security Access Code for Device Port 5
Contains the security access code for device port 5. This register holds up to 7
digits ranging from 0 to 9, * and #. Factory preset to 55.
REGISTER 16 - Multiple Polling Code
This register contains the multiple polling code (MPC). The MPC should be
placed at the beginning or end of a security access code. After a device has
completed its communication and if the correct MPC is detected, the ACP will
seize the line. This process allows multiple polling with one call. The register
must contain two digits. Factory preset to ##.
REGISTER 26 Security Access Code for Device Port 6
Contains the security access code for device port 6. This register holds up to 7
digits ranging from 0 to 9, * and #. Factory preset to 66.
REGISTER 27 Security Access Code for Device Port 7
Contains the security access cede for device port 7. This register holds up to 7
digits ranging from 0 to 9, * and #. Factory preset to 77.
REGISTER 28 Security Access Code for Device Port 8
Contains the security access cede for device port 8. This register holds up to 7
digits ranging from 0 to 9, * and #. Factory preset to 88.
REGISTER 29 Security Access Code for Device Port 9
Contains the security access cede for device port 9. This register holds up to 7
digits ranging from 0 to 9, * and #. Factory preset to 99.
WARNING: For registers 11 through 15 or 26 through 29, DO NOT program any
of the security access codes to segments of the programming code (**7764#)
TO ENTER PROGRAMMING MODE
To enter programming mode, pick up the receiver of the phone that is plugged
into device port 1 and dial **7764#. After dialing the string, 3 quick high beeps
should be heard. This affirms entry into the programming menu.
To program individual registers, press the register number you wish to program
and the desired digits immediately in a contiguous string (as an example: 023 to
set register 02 to a value of 3). If an error in entry is detected, a single low pitch
beep will be heard followed by a short space, then 3 quick high beeps. The 3
quick high beeps tell you to proceed.
TO RESET ALL REGISTER VALUES TO FACTORY PRESET
Press 60 while in programming mode to reset all registers to factory defaults.