Multi-Tech Systems MT3334HD8 Network Card User Manual


 
4 S-Registers
CommPlete Communications Server 51
Reading and Assigning S-Register Values
Use the S command to assign a value to an S-register and to read an S-registers current value.
To read an S-register value, in terminal mode, type S, the S-register number, and a question mark (?), and
press ENTER. For example, to display the value of register S7, type ATS7? and press ENTER. The answer will
appear as a three-digit decimal number (e.g.,
045
).
To assign a new value to an S-register, type S, the S-register number, an equals sign (=), and a decimal
number. Convert all ASCII characters to their decimal equivalents before entering them. S-register decimal
values are 0127 for ASCII characters, and 0255 for numeric values. To make the change permanent, use
the &W0 command.
Examples of Assigning Values
1. Lets assume you want to have longer pauses caused by the comma in a dial command: five seconds
instead of two. Type ATS8=5 to assign 5 as the value for register S8. The modem will now pause five
seconds for every comma in a dial command.
2. Or lets assume that you wish to configure the modem to answer incoming calls after the thirtieth
ring instead of after the first ring. To configure register S0
with a value of 30, type ATS0=30 and
press E
NTER.
3. Or lets say you are calling long distance to another country code, and it is taking a long time to
connect. The register S7
(abort timer) factory default setting of 45 seconds is insufficient; the abort
timer times out and cancels the call before a connection is made. To change the S7
value to 55
seconds, type ATS7=55 and press E
NTER. Now, after dialing, the modem allows 10 more seconds for
a carrier signal before aborting the call. The additional 10 seconds should provide enough time for
international calls.
Examples of Reading Values
1. To verify that you entered the value correctly in the preceding examples, type ATS8? and press
E
NTER in the first example, ATS0? in the second example, and ATS2? in the third example. You
should receive the responses
005
,
030
, and
055
, respectively.
2. When configuring S-registers, it is a good practice to include the verification read command in the
same command string as the configuration assignment command. In the three preceding examples,
type ATS8=5S8?,
ATS0=30S3?, and ATS7=55S7?, respectively.
AT Commands that Affect S-Registers
For maximum throughput, the MT3334HD8s default configuration is for originating a call to another
33,600 bps modem that supports error correction, data compression, and flow control. If the receiving
modem is not compatible, the MT3334HD8 can match any ITU-T or Bell standard modem (but not
proprietary protocols).
If you require a different configuration for your application, for example, if you want to use an
MT3334HD8 modem strictly as an auto answering device, or for service that does not support error
correction, you can selectively change the command parameters and S-register values in active memory and
save the new values by using the &W command.