Multi-Tech Systems MT5600DSVD Modem User Manual


 
MultiModemDSVD User Guide 4 AT Commands, S-Registers, and Result Codes
33
Command: &Zy
=x
Store Telephone Number
Values: y = 03
x = Dialing command
Default: None
Description: Stores telephone dial string x in memory location y. Each tele-
phone number dial string can contain up to 34 digits. Dial the
stored number using the command ATDS=y.
Note: DTR dialing uses the number stored in memory location 0.
Command: %C
n
Data Compression Control
Values: n = 0, 1, 2, or 3
Default: 3
Description: Enables or disables data compression negotiation. The modem
can only perform data compression on an error-corrected link.
%C0 Disables data compression.
%C1 Enables MNP 5 data compression negotiation.
%C2 Enables V.42bis data compression negotiation.
%C3 Enables both V.42bis and MNP 5 data compression negotiation.
Note: This command controls both V.42bis and MNP-5 data
compression, whereas the &E14 and &E15 commands control
only V.42bis data compression. The command in effect is the
one last entered.
Command: %E
n
Line Quality Monitor
Values: n = 0, 1, or 2
Default: 2
Description: Controls whether or not the modem will automatically moni-
tor the line quality and request a retrain (%E1) or fall back to a
lower speed when line quality is insufficient and fall forward
to a faster speed when line quality is sufficient (%E2).
%E0 Disable line quality monitor and auto-retrain.
%E1 Enable line quality monitor and auto-retrain.
%E2 Enable line quality monitor and fallback/fall forward.
Command: %L Line Signal Level
Values: None
Default: None
Description: %L Returns a value that indicates the received signal level. The
value returned is a direct indication (DAA-dependent) of the
receive level at the MDP, not at the telephone line connector.
For example, 009 = -9 dBm, 043 = -43 dBm, and so on.
Command: %Q Line Signal Quality
Values: None
Default: None
Description: %Q Reports the line signal quality (DAA-dependent) as a three-
digit number. Returns the higher order byte of the EQM value.
Based on the EQM value, retrain or fallback/fall forward may
be initiated if enabled by %E1 or %E2.