Multi-Tech Systems MT5634SMI V.92 Modem User Manual


 
Chapter 4 – Voice Commands
Multi-Tech Systems, Inc. SocketModem MT5634SMIxx Reference Guide (S000263C) 126
AT+VSM=128, 7200, 128, 0; +VEM=FFFFFFFF8; +VSD=128, 50
OK The modem agrees.
AT+VSM=129, 7200, 0, 0 The PC changes its PC/modem interface rate to 38400 bps and selects a
compression method with the least sensitive setting, with the goal of playing a
message with less distortion, and at 7200 samples per second. (Assume that
the PC issued a +VSM=? command earlier.)
OK The modem agrees.
AT+VLS=4 The modem selects the speaker. The modem had earlier reported that a
speaker was available.
OK The modem agrees.
AT+VTX The PC selects the Voice Transmit mode.
CONNECT The modem agrees.
<Data> The PC delivers <DLE> shielded and silence compressed voice data across the
PC/modem interface.
<DLE> <ETX> The PC indicates the end of the Voice data stream.
OK The modem indicates it is in Voice Command mode.
AT+VLS=0 The PC deselects all devices.
OK The modem agrees.
The PC switches to Data mode, Command mode, and autobauding enabled:
AT+VIT=0; +VPR=0; +FCLASS=0
OK The modem agrees.
Answer Phone, Play Greeting Message, and Record Message Example
Command Response
AT+FCLASS=8; The DCE switches to Voice mode. The DTE selects a fixed
AT+VIT=60; DTE-DCE interface rate. The DTE knows from the sample
+VPR=16 rate selected earlier and the bits-per-sample that the DTE-DCE interface rate
should be 38400 bps. The DTE-DCE Inactivity Timer starts with 60 seconds.
OK DCE agrees (to the old DTE/DCE interface rate).
AT+VSM=129, 7200, 0, 0 DTE changes its DTE/DCE rate to 38400 bps and selects a compression
method with the least sensitive setting, with the goal of recording a message
with less distortion, and at 7200 samples per second. Assume that the DTE
issued a +VSM=? command earlier.
OK The DCE agrees.
AT+VSD=127, 20 DTE selects a silence detection period of 2 seconds.
AT+VLS=0 DTE selects a silence detection period of 2 seconds with the least sensitive
setting (for detecting the end of voice recording).
OK The DCE agrees.
AT+VIT=0; The DTE selects the Data mode with autobauding, and disables +VPR=0;
automatic DCE answering. The DCE waits for a phone call.
+FCLASS=0 (not necessarily in Data mode).
S0=0
OK The DCE agrees.
RING At some time, a remote station calls.
AT+FCLASS=8; The DCE switches to Voice mode. The DCE selects a fixed AT+VIT=60;
DTE/DCE Interface Rate. The DTE knows from the sample AT+VPR=16; rate
selected earlier and the bits per sample that the DTE/DCE Interface Rate should
be 38400 baud. The DTE/DCE Inactivity Timer starts with a value of 60 seconds.
OK The DCE agrees (at the old DTE/DCE Interface Rate).
AT+VLS=0 The DTE selects all devices.