Murphy CDV100F Network Card User Manual


 
Section 78 00-02-0618
04-10-07 - 8 -
Specifications
Power Supply
Operating voltage:
12V range (link L2-in place) 7-16 VDC
24V range (link L2-cut) 19-30 VDC
Current consumption:
CDV100F: 25mA typical
CDV300R: 50mA, typical (2 LEDs lit)
Inputs
CANbus:
SAE J1939 protocol, Input fitted with 120 Ohm terminating resistor, removable by cutting link L1.
Outputs
Oil pressure gage, coolant temperature gage
Link selectable for Murphy, VDO or Datcon electric gages
Tachometer
Pulsed DC, approximately 121 Hz @ 1500 RPM
General
Overall dimensions (W x H x D)
Case: 2.7x3.8x0.9 inch (68x96x22mm) (allow 2 inches (50mm) depth with connector)
Weight: approximately .18 lbs (80g)
Environmental sealing
IP60
CDV300R: IP65 from front with CDVG gasket (included)
Operating ambient temperature: -40° F to 185° F (-40°C to +85°C)
Storage temperature: -67°F to 221°F (-55°C to 105°C)
Operating Vibration: .02 lbs (10g) (5-2000 Hz)
Operating Shock: .11 lbs (50g) (3-axis)