National Instruments GPIB-PC Network Card User Manual


 
Appendix B Common Errors and Their Solutions
©National Instruments Corp. B-3 GPIB-PC User Manual
EADR(3)
Error Condition: GPIB-PC (GPIB0 or GPIB1) is not addressed
correctly.
Solutions:
Use IBCMD to send the appropriate Talk or Listen address
before attempting an IBWRT or IBRD.
If calling IBGTS with the shadow handshake feature, call
IBCMD to ensure that the GPIB ATN line is asserted.
EARG(4)
Error Condition: Invalid argument to function call.
Solutions:
Errors received from IBIC:
- Verify syntax in Section Five.
- Make sure the address of the board in IBCONF does not
conflict with that of a device.
Errors received when running your application program:
- Verify syntax in Section Four.
- Make sure the address of the board in IBCONF does not
conflict with that of a device.