National Instruments NI 9472 Network Card User Manual


 
© National Instruments Corp. 19 NI 9472/9474
Output delay time (full load)
NI 9472.......................................100 μs max
NI 9474.......................................1 μs max
MTBF
NI 9472.......................................1,113,301 hours at 25 °C;
Bellcore Issue 2, Method 1,
Case 3, Limited Part Stress
Method
NI 9474.......................................479,889 hours at 25 °C;
Bellcore Issue 2, Method 1,
Case 3, Limited Part Stress
Method
Note Contact NI for Bellcore MTBF specifications
at other temperatures or for MIL-HDBK-217F
specifications.
NI 9472 Power Requirements
Power consumption from chassis
Active mode ...............................230 mW max
Sleep mode .................................0.4 mW max