National Instruments NI TB-2709 Network Card User Manual


 
© National Instruments Corporation 9 NI TB-2709 Installation Guide
Physical
Dimensions
Height.............................................. 10.7 × 8.6 × 2.0 cm
(4.2 × 3.4 × 0.8 in.)
Weight............................................. 144.6 g (5.1 oz)
I/O connectors
68-position SCSI-II type................. 1, female
SMB jacks....................................... 9
14-pin auxiliary connector .............. One, Molex 14-pin microfit
connector
Shock and Vibration
Operational shock .................................. 30 g peak, half-sine, 11 ms pulse
(Tested in accordance with
IEC-60068-2-27. Test profile
developed in accordance with
MIL-PRF-28800F.)
Random vibration
Operating ........................................ 5 to 500 Hz, 0.3 g
rms
Nonoperating .................................. 5 to 500 Hz, 2.4 g
rms
(Tested in accordance with
IEC-60068-2-64. Nonoperating
test profile exceeds the
requirements of
MIL-PRF-28800F, Class 3.)
Environment
The NI TB-2709 is intended for indoor use only.
Operating temperature............................ 0 to 55 °C
Storage temperature ............................... –20 to 70 °C
Relative humidity................................... 10 to 90% noncondensing
Pollution Degree .................................... 2