1) SP console screen and operation during AC LINK setup
* The above display is an example. The screen may differ depending on the system
configuration.
iSPyz:---> sg
<ENTER>
<= Enter sg and press Enter
Display and modify settings of system and iSP.
s) System settings
i) iSP settings
a) display all settings
Select ? (s/i/a/CR=exit) : s <= Enter s and press Enter
System setting menu:
c) system common settings (maintenance only)
p) partition settings (maintenance only)
b) partition boot methods and Hot-plug permission
a) display all settings
Select ? (c/p/b/a/CR=back) : b <= Enter b and press Enter
Partition boot methods and Hot-plug permissions:
| |Wake |Hot-Plug permission
part.|AC- | On | PCI-card | CELL | PCI-D | PCI-E
|LINK | LAN |PCI(X)|PCE-EX| add |remv |swap | add |remv | add |remv
-----+-----+-----+------+------+-----+-----+-----+-----+-----+-----+------
0 | off | off | YES | no | no | no | no | no | no | no | no
1 | off | off | YES | no | no | no | no | no | no | no | no
2 | off | off | YES | no | no | no | no | no | no | no | no
3 | off | off | YES | no | no | no | no | no | no | no | no
4 | off | off | YES | no | no | no | no | no | no | no | no
5 | off | off | YES | no | no | no | no | no | no | no | no
6 | off | off | YES | no | no | no | no | no | no | no | no
7 | off | off | YES | no | no | no | no | no | no | no | no
Modify? (y/[n]) : y <= Enter y and press Enter
Enter partition number? (0-7/CR=back) : 0
AC link mode (o[n]/of[f]/CR=skip) :
<= Enable AC LINK and press Enter
Wake on LAN (o[n]/of[f]/CR=skip) :
Hot plug permission:
PCI(X) card? (y[es]/n[o]/CR=skip) :
PCI-Ex card? (y[es]/n[o]/CR=skip) :
(Omitted)