NEC NX7700i/5040H-32 Server User Manual


 
Base Module
855-900547-200 2-54
cmd arg1 arg2 arg3 arg4 Description
pbayx - - - Enable the Power Bay.
x is a Power Bay number. The allowable
value of x is as follows:
For 32Way:
0, 1: Power Bay numbers within the Main
Cabinet
2, 3: Power Bay numbers within the
Expansion Cabinet
For 8Way:
0: Power Bay number inside the chassis
1: Power Bay number outside the chassis
For ISPF:
0: Power Bay number inside the chassis
clkx - - - Enable the CLK.
x is a CLK number (0 or 1).
The CLK is installed only in the 32Way
model.
xbxcx [all] - - Enable the XBX Card.
x is an XBX Card number (0-3).
If arg2 is omitted, only the XBX Card is
enabled, with its subcomponents left
disabled.
If “all” is specified for arg2, XBX Card is
enabled including all of its subcomponents.
xbxxy [all] - - Enable the XBX LSI.
x is an XBX Card number (0-3).
y is an XBX LSI number (0-1) on an XBX
Card.
If arg2 is omitted, only the XBX Card is
enabled, with its subcomponents left
disabled.
If “all” is specified for arg2, the XBX Card is
enabled including all of its subcomponents.
cellx [all] - - Enable the CELL Card.
x is a physical CELL number (0-7).
If arg2 is omitted, only the CELL Card is
enabled, with its subcomponents left
disabled. In this case, console operation will
be rejected if essential components are
disabled.
If “all” is specified for arg2, the CELL Card is
enabled including all of its subcomponents.
cnxxy - - - Enable the CNX LSI.
x is a physical CELL number (0-7).
y is a CNX number (0-1) within a CELL.
CNX1 exists only in the 32Way(H) model.
procxy - - - Enable the Processor.
x is a physical CELL number (0-7).
y is a Processor number (0-3) within the
CELL.
mmxxy [all] - - Enable the MMX.
x is a physical CELL number (0-7).
y is an MMX number (0-3) within the CELL.
If arg2 is omitted, only the MMX is enabled,
with its subcomponents left disabled.
If “all” is specified for arg2, the MMX is
enabled including all of its subcomponents.