June 2004 NEC Business Solutions Ltd
36 IAD (8)-U( ) ETU Web Programming
Doc. No. 8684 - Release 1.0
June 2004
S
ECTION
3
IAD (8)-U( ) ETU WEB
P
ROGRAMMING
When installed for the first time, the IAD (8)-U( ) ETU, comes up with factory
set default parameters as shown in Table D-2 Factory Network Settings.
In this configuration, the ETU cannot run in any randomly given
environment, and its parameters must be redefined before the IAD (8)-U( )
ETU can work in your environment.
1. Boot up a PC with IP Address: 192.168.1.X, Subnet Mask:
255.255.255.0. Connect to the IAD(8)-U( ) either via a crossover cable
or a small hub.
2. Connect to the IAD (8)-U( ) ETU via your Web Browser to the following
link:
http://192.168.1.100/
The IAD (8)-U( ) ETU supports Microsoft Internet Explorer 5.0
and higher.
3. When the login screen appears, enter the Login ID and password. Click
login.
Default login ID = admin
Default password = password
4. Set the IP Address, Subnet Mask, Host Name, and Default IP
parameters in the IAD (8)-U( ) ETU Card tab and select Submit.
5. Set the IP Station Encoding Preference, Packet Size, Jitter Depth and
the IP Address (or use DHCP if using a DHCP Server) under the Port
Tab and select Submit.
6. Select the System tab, then select Reset the Card. The ETU goes
through a reboot cycle. This may take a few minutes.
7. Disconnect the crossover cable and connect the IAD (8)-U( ) ETU
(MEGACO Station) to your network.
The ETU is now ready for operation.
Table D-2 Factory Network Settings
Host Name
neciad
IP Address
192.168.1.100
Subnet Mask
255.255.255.0
Default Gateway
192.168.1.1