Environmental Specifications
Certifications
Condition Operating Specification Storage Specification
Temperature 0° to 40° C (+32° to +104° F) 40° to +85° C (40° to +185° F)
Relative humidity 5 to 85% non-condensing
(40° C, 16 hour dwells at extremes)
5 to 95% non-condensing
10° C/hour
Altitude up to 3,050 meters (10,000 feet) up to 10,750 meters (35,000 feet)
Shock 10g, 1/2 sine wave, 11 msec 60g, 1/2 sine wave, 11 msec
Vibration, peak to peak
displacement
0.005 in. max (5 to 32 Hz) 0.1 in. max (5 to 17 Hz)
Vibration, peak
acceleration
0.25g (5 to 500 Hz)
(Sweep Rate = 1 octave/minute)
0.25g (5 to 500 Hz)
(Sweep Rate = 1 octave/minute)
Category Compliance
EMC CISPR 22/CISPR 24 (International)
FCC, CFR 47 Part 15, Class A (USA)
CSA CSO3 Class A (Canada)
VCCI Class A (Japan)
EN 55022/EN 55024 (with required subtest) (Europe)
AS/NZ 3548 (Australia/New Zealand)
CNS 13438 (Taiwan)
MIC (Korea)
Safety IEC 60950 (International)
National Deviation per CB Member Countries to IEC 60950
UL 1950, (USA)
CSA 22.2, No. 950 (Canada)
EN 60950 (Europe)
NOM-D19-SCFI - 1998 (Mexico)
IEC 60950 with deviations (Argentina)
IEC 60950 with deviations (Chile)