Nortel Networks BMD00007 Switch User Manual


 
Alteon OS Command Reference
246
The Configuration Menu BMD00007, November 2007
/cfg/l2/failovr/trigger
Failover Trigger Configuration
[Trigger 1 Menu]
amon - Auto Monitor Menu
limit - Limit of Trigger
ena - Enable Trigger
dis - Disable Trigger
cur - Display current Trigger configuration
Table 6-50 Failover Trigger Menu Options (/cfg/l2/failovr/trigger)
Command Syntax and Usage
amon
Displays the Auto Monitor menu for the selected trigger. To view menu options, see page 247.
limit <0-2>
Configures the
minimum number of operational links allowed within each trigger before
the trigger initiates a failover event. If you enter a value of zero (0), the switch triggers a
failover event only when no links in the trigger are operational.
ena
Enables the selected trigger.
dis
Disables the selected trigger.
cur
Displays the current failover trigger settings.