Nortel Networks NN10035-111 Projector User Manual


 
14 Upgrades
NN10035-111 Standard MCP 1.1 FP1 (02.02) April 2003 Copyright © 2003, Nortel Networks
Nortel Networks Confidential
reboots the Peripheral CPUs. When the RTP Media Portal recovers
from the reset, it is running (UNLOCKED) with the upgraded software.
Note: It is possible to update one RTP Media Portal and reboot it
while the other half shelf is running the load that has not been
updated. Once one half shelf is updated, the other half shelf can be
locked, updated, and rebooted. Upgrading all RTP Media Portals
concurrently will cause a service outage.
The length of outage due to the reboot is approximately 3-5
minutes.
Note 1: Software loads are encrypted for security reasons.
Note 2: If a component upgrade fails, it does not roll back
automatically. A roll back prompt appears. If the upgrade is not
successful, note as much of the event as possible and contact your
next level of support.
Task flows
To avoid any problems with the SIP Application Module, the following
procedure describes the steps that must be followed when updating a
software load for the RTP Media Portal component.
From the System Management Console:
1 Shutdown the RTP Media Portal component. See “Shutdown the
RTP Media Portal component” on page 14.
2 Update the software load for the RTP Media Portal component.
See “Update a software load” on page 15.
Shutdown the RTP Media Portal component
The following procedure describes how to shutdown the RTP Media
Portal component:
From the System Management Console
1 Select the RTP Media Portal Server, select Components and
then select the appropriate RTP Media Portal component.
2 To Shutdown the component, either right-click and select
Shutdown or select Shutdown from the Operations menu.
3 The RTP Media Portal component will shutdown gracefully and
go into a LOCKED state, as seen in the General Information
Area of the System Management Console.