Chapter 2 Install and Initialize the Uninterruptable Power Supply 25
UPS Installation and Configuration Guide
After 15 minutes, the service switches back to the UPS to enable the UPS (if the UPS was
originally selected and enabled).
To extend the Console time, stop the UPSConsoleToggle using the command “Net Stop
UPSConsoleToggle”.
The UPS service needs to be enabled from the Unified Manager when the user ends the
console session.
Enable UPSConsoleToggle
Use this procedure to enable the UPSConsoleToggle service.
1 Wait for all services to be up and running.
2 Verify that the UPS service is running.
3 If UPS service is running, change its start-up type to Manual-Start and the console CMDRMT
service to Auto-Start, then stop UPS service and start Console service.
4 Wait for 15 minutes.
5 Toggle the UPS/Console.
6 Change the console start-up type to Manual-Start and the UPS to Auto-Start. This stops the
console service and starts the UPS service.
7 Stop the UPSConsoleToggle service.
8 This procedure is complete.