N-Tron 100 Series Switch User Manual


 
5/17/2007 12
CONNECTING THE UNIT
For the 100BaseFX Fiber Optic port, remove the dust cap(s) from the fiber optic connector and connect the
fiber optic cables. The TX port on the local unit should be connected to the RX port of the far end device, and
the RX port should be connected to the TX port of the far end device.
For 10Base-T ports, plug a Category 3 (or greater) twisted pair cable into the RJ45 connector. For
100Base-T ports, plug a Category 5 (or greater) twisted pair cable into the RJ45 connector. Connect the
other end to the far end station. Verify that the LNK LED’s are ON once the connection has been
completed. To connect any other port to another Switch or Repeater, use a standard Cat5 straight through or
crossover cable.
TROUBLESHOOTING
1. Make sure the (Power LED) is ON.
2. Make sure you are supplying sufficient current for the version chosen. Note: The Inrush current will
exceed the steady state current by ~ 2X.
3. Verify that Link LED’s are ON for both ports.
4. Verify cabling used between stations.
5. Verify that cabling is Category 3 or greater for 10Mbit Operation.
SUPPORT
Contact N-TRON Corp. at:
TEL: 251-342-2164
FAX: 251-342-6353
www.n-tron.com
support@n-tron.com