Oki 720 Printer User Manual


 
76 Appendix B: Menu Selections
DSR Signal. Applies only when optional Interface is installed. Valid (factory default) or In-
valid. Used with Ready / Busy protocol to select the way your system handles the DSR Signal.
DTR Signal. Applies only when optional Serial Interface is installed. Ready on Power
Up (factory default) or Ready on Select. Change to Ready on Select if the DTR signal
is required when the printer is selected; leave as Ready on Power Up if DTR signal is
required when printer is turned on.
Emulation Mode. IBM PPR (factory default), Epson FX, or ML. Selects the Printer com-
mand set you want your printer to use: IBM Proprinter III, Epson FX, or OKI Microline.
ESC SI Pitch. Designate the function of ESC SI command to 17 cpi setting (default) or
20 cpi setting.
Form Tear-Off. Off (factory default), 500 ms, 1 sec, or 2 sec. Form Tear-Off advances
the paper to the perforation so that you can tear off a sheet of continuous-forms pa-
per. You can turn this feature off, or you can select a time interval for the printer to
wait before advancing the paper.
Graphics. Bi-directional (factory default) or Uni-directional. Bi-directional graphics
print faster than uni-directional graphics, but uni-directional graphics have better
print registration. Bi-directional graphics printing can be optimized by adjusting the
Print Registration setting in the Menu.
I-Prime. Buffer Print (factory default), Buffer Clear, or Invalid. Determines how the printer
will react to the I-Prime signal from your software. With the factory default engaged,
when the printer receives the I-Prime signal, it will print out the contents of the buffer
before resetting. Change the setting to Buffer Clear if you wish the printer to dump the
contents of its buffer immediately upon receiving the I-Prime signal. Change to Invalid if
you want the printer to ignore your software’s I-Prime signal. This will permit you to
enter settings through the printer’s control panel which will not be automatically over-
ridden by the software’s settings when the I-Prime signal is sent.
Language Set. American (factory default), French, German, British, Danish I, Swed-
ish, Italian, Spanish I, Japanese, Norwegian, Danish II, Spanish II, Latin American,
French Canadian, Dutch, or Publisher. Replaces certain symbols with special charac-