Olympia CM 701 Cash Register User Manual


 
Quick Reference
CM 701/702/711/712 Cash Register Quick Reference
Olympia 5.2005 Page 10 All Rights Reserved
- Table, continued -
Note: The standard settings appear in bold print.
System option no. Status no. Setting
0 Zero skip printing for Z-report
11
1 No zero skip printing for Z-report
0 Zero price of a PLU or department not permitted
12
1 Zero price of a PLU or department permitted (default)
0 No special European rounding
1 European rounding: Swiss
2 European rounding: Swedish
13
3 European rounding: Danish
0 Printing of an additional bill permitted
14
1 Printing of an additional bill not permitted
0 Z1 and Z2 counters are not deleted after Z-financial report printout
15
1 Z1 and Z2 counters are deleted after Z-financial report printout
0 Grand Total is not deleted after Z1 financial report printout
16
1 Grand Total is deleted after Z1 financial report printout
0 Grand Total is not printed on the financial report
17
1 Grand Total is printed on the financial report
0 Calculator mode
18
1 Journal mode
0
Basic currency is the local currency (amount ÷ conversion factor)
19
1
Basic currency is foreign currency (amount × conversion factor)
0 Refunds are printed on the financial report
20
1 Refunds are not printed on the financial report
The system options set can be printed out.
Input Display Confirm by pressing
Printing system settings:
Set the key to PRG
Press
9 6 times, conclude by
pressing
q.
999999
9999,99
q
Clearing errors
Incorrect entries and error status (acoustic signal) can be cleared by pressing g.
Registration according to departments
Enter price without decimal point (max. 7 digits).
Price Department
PPPPPPP
A
Or: If the same PLU should be registered several times:
No. of PLUs Price Department
NN
h
PPPPPPP
A
The sum of NN x PPPPPPP is limited to the maximum capacity of the cash register.