Omega Vehicle Security DPS3300 Scanner User Manual


 
Page 26
TROUBLE SHOOTING
If the meter locks on a particular display, unplug and plug in again to unlock the display. A total reset clears the memory
and defaults all values to zero. To perform this reset, re-apply power with RESET key pressed in.
Factory Channel settings:
To obtain factory preset values simply re-apply power with SDIGT key pressed in. This will also clear memory of any
erroneous values and is the preferred method of resetting a unit that might be malfunctioning due to corrupted memory .
Factory default settings for Thermocouple, voltage, current and milli-volt are:
CURRENT VOLTAGE. MILLIVOLT T/C
PARAMETER
INPUT INPUT INPUT INPUT
HIGH SCALE 20.000 10.000 100.00 J
LOW SCALE 0.000 0.000 0.000 J
OFFSET 0.00 0.00 0.00 J
TARE 0.000 0.000 0.000 J
ERROR MESSAGES AND SOLUTIONS
ERROR MESSAGES AND SOLUTIONS
ERROR MESSAGE ERROR CONDITION SOLUTION
'EE EROR' The unit was unable to If the message keeps coming up,
save programmed value unplug the unit and reapply power.
in EEPROM -- possible If the unit still displays the error
failure of EEPROM. message, send it in for repair.
If error message followed by
8.8.8.8.8.8.8.and the revision
number are displayed occasionally,
it is an indication that power
line is very noisy and needs a line filter.
'CARD ER' Too much noise on 1. If message shows occasionally,
input signals or problem it indicates that input signal s have
with Scanner card. too much high voltage noise.
Provide signal filters.
2. Unplug and plug the meter again
to recycle power.
3. Scanner card defective -- send in
for repair
'HIGH AC NOISE' High AC noise on input 1. If message shows occasionally,
signals or incoming AC it indicates that input signals or
line interfering with the AC line has too much high
operation of the unit voltage noise.
2. Provide line and signal filters.